Field Change Order: 2030 Date of Issue : 23rd November 1992 Applicable to : A3020, A4000 Reason for Issue: Customers fitting Genlock expansion cards to the above products will experience synchronization problems due to a PCB artwork error. The Sync input to the ARM 250 (IC 13 pin 121) is taken directly to 0 volts instead of being routed via LK6 pin 3. LK6 pin 3 is also incorrectly connected directly to 0 volts. Types Affected: Early A3020 - iss. 1 PCBs - 0194,500 Early A4000 - iss. 1 PCBs - 0194,600 Description of Change: Dealers to return faulty PCB modules under FASTRAK process, to :- Acorn Computers Ltd, Cambridge Technopark, 645 Newmarket Road, Cambridge, CB5 8PD. Marked for the attention of Ann Wood. Faulty unit must be labelled 'FCO 2030 - Genlock fault' Claim Procedure: N/A Rework Doc. Reference: FCO Credit Rate: Special Instructions: